Training for Tradies – for online and face to face training, click here ›

  • Homeowners
  • Specifiers
  • Installers
  • Contact Us
Rheem Logo
  • Water Heating
    Rheem Products
    For the Home Electric Water Heating Gas Water Heating Heat Pump Water Heating Solar Water Heating Pool & Spa Heating Boiling - On-Tap Accessories
    Commercial Use Commercial Gas Continuous Flow Commercial Electric Continuous Flow Commercial Heat Pump Water Heating Heavy Duty Electric Storage Heavy Duty Gas Storage Storage Tanks Dairy Water Heating Raypak Hot Water Pool & Spa Heating Commercial Solar Water Heating Guardian Warm Water Heat Exchanger Technology Pump Sets Boiling - Lazer Boiling - Zip Boiling - On-Tap Accessories
    Boiling Water Boiling - On-Tap Boiling - Lazer Boiling - Zip Accessories
    • For the Home
      • Electric Water Heating
      • Gas Water Heating
      • Heat Pump Water Heating
      • Solar Water Heating
      • Pool & Spa Heating
      • Boiling - On-Tap
    • Commercial Use
      • Commercial Gas Continuous Flow
      • Commercial Electric Continuous Flow
      • Commercial Heat Pump Water Heating
      • Heavy Duty Electric Storage
      • Heavy Duty Gas Storage
      • Storage Tanks
      • Dairy Water Heating
      • Raypak Hot Water
      • Pool & Spa Heating
      • Commercial Solar Water Heating
      • Guardian Warm Water
      • Heat Exchanger Technology
      • Pump Sets
      • Boiling - Lazer
      • Boiling - Zip
      • Boiling - On-Tap
    • Boiling Water
      • Boiling - On-Tap
      • Boiling - Lazer
      • Boiling - Zip
  • Solar Solutions
  • Sustainability
  • Buyers Guide
    Rheem Products
    Product Selector Brochure Library Where To Buy Fix My Rheem Video Guides
    • Product Selector
    • Brochure Library
    • Where To Buy
    • Fix My Rheem
    • Video Guides
  • Support
    Rheem Products
    Fix My Rheem Warranty Claim Residential Manuals & Warranties Commercial Warranties Frequently Asked Questions Flood Affected
    • Fix My Rheem
    • Warranty Claim
    • Residential Manuals & Warranties
    • Commercial Warranties
    • Frequently Asked Questions
    • Flood Affected
  • About Us
    Rheem Products
    Why Choose Rheem? Vision & Values Compliance Careers Rheem Blog Corporate Social Responsibility Save the kiwi
    • Why Choose Rheem?
    • Vision & Values
    • Compliance
    • Careers
    • Rheem Blog
      • How a Green Loan Can Fund Your Rheem Solar Solution
      • Rheem Training for Tradies
      • Rheem New Zealand: A Brief History
      • Dogs causing plenty of ruff – but rewarding – days for Northland Save the Kiwi staff member
      • Heat Pump Water Heating: The Future of Hot Water
      • Rheem Factory Solar Installation Success
      • End of an Era
    • Corporate Social Responsibility
    • Save the kiwi
  • Info for:
    Homeowners Specifiers Installers Contact Us Log Out
    MyRheem Pro
MyRheem Pro
  1. Home
  2. Products
  3. Commercial Use
  4. Commercial Heat Pump Water Heating
  5. Commercial Heat Pump (discontinued)
  6. Heat Pump 95302200D/A
Commercial Heat Pump (discontinued) 95302200D/A

Commercial Heat Pump (discontinued)
Heat Pump 95302200D/A

Enquire
Where to Buy
Compare
  • Overview
  • Specifications
  • Technical Documents

The Rheem Commercial Air to Water Heat Pump delivers up to 65°C hot water with the use of R134a refrigerant. Fine tuning of the system performance in our world class psychrometric test facility has resulted in a Coefficient of Performance (COP) of 4.0 which increases efficiency and reduces energy consumption, whilst an increased recovery rate provides more hot water in a shorter time frame.

 

Thermostat Setting Max Dimensions Installation Location Electrical Connection
65 °C 980 x 1150 x 565/585mm HxW Outdoor 3 Phase / 415V / 50Hz V AC/ Hz
Thermostat Setting Max 65 °C
Dimensions 980 x 1150 x 565/585mm HxW
Installation Location Outdoor
Electrical Connection 3 Phase / 415V / 50Hz V AC/ Hz

Commercial Heat Pump (discontinued) 95302200D/A

Product Specifications

TPR Valve Connection
1000
Thermostat Setting Max
65 °C
Dimensions
980 x 1150 x 565/585mm HxW
Installation Location
Outdoor
Electrical Connection
3 Phase / 415V / 50Hz V AC/ Hz
Weight Empty Approx
130 kg
Max Water Supply Pressure w/out ECV
800 kPa
Max Water Supply Pressure with ECV
650 kPa
Storage Capacity per Heat Pump
400-4000 Litres
Power Input
4.1 kW
Heating Capacity @ 20°C
16.4 kW
Recovery @ 50°C Rise at 20°C
282 L/hr
Refrigerant
R134a
Expansion Control Valve Setting
850 kPa
Weight Full Approx
135 kg
Sound Pressure Level @1m
61 dBA
Heat Pump Pipe Sizing Chart
Number of Heat Pumps in Parallel 1 2 3 4 5 6
Primary Pump Grundfos CM 3-2
Branch Size 32 32 32 32 32 32
Header Size 32 50 65 65 80 80

Note: Header pipe sizing is based on a total length of 20m of primary flow and return piping and 20 bends, excluding equa-flow manifolds on storage tanks and heat pumps @ 1.6m/sec velocity. One pump per Heat Pump.

Recovery
 Ambient Temperature (°C)  0 5 10  15 20 25 30 35 40
 Output (kW) 9.0  11.1  13  14.6  16.4 18.3  20.3  22.2   24.1
 Recovery - Litres p/hour @ 20°C rise 387 478 558 627 705 789 872 956 1036
 Recovery - Litres p/hour @ 30°C rise 258  319  372  418  470  526  582  638  691 
 Recovery - Litres p/hour @ 35°C rise 221  273  319  358  403  451  499  546  592 
 Recovery - Litres p/hour @ 40°C rise 194  239  279  313  353  394  436  478  518 
 Recovery - Litres p/hour @ 45°C rise 172  213  248  279  313  351  388  425  461 
 Recovery - Litres p/hour @ 50°C rise 155  191  223  251  282  316  349  383  415 
 Recovery - Litres p/hour @ 55°C rise 141  174  203  228  256  287  317  348  377 
Heat Pump Clearances
   

 952022 Model
(Ducted Exhaust)

 953022 Model
(Non-Ducted Exhaust)
Front mm 600 600
Back (vertical discharge models)  mm  50  50 
Back (horizontal discharge models)  mm  1200  1200 
Sides mm  600  600 
Top (vertical discharge models)  mm  800  1200 
Top (horizontal discharge models) mm  50  50 

Technical Documents

Technical Document
Commercial Heat Pump Installation Overview
2.9 MB
Commercial Heat Pump Installation Guide
1022 KB
Commercial Heat Pump Spare Parts Guide
666 KB
Commercial Heat Pump Service Manual
6 MB
Revit - 953022 Vertical 11
888 KB
Revit - 953022 Vertical 12
896 KB
Commercial & Industrial Guide
18 MB
St Mary's Tower Retreat Centre Case Study
298 KB
Paragon Fitness Centre Case Study
259 KB
Southern Ocean Lodge Case Study
415 KB
Technical Document

Related Products

Commercial Heat Pump (discontinued) 95202200D/A
Heat Pump 95202200D/A
Commercial Heat Pump (discontinued) 95302200D/H
Heat Pump 95302200D/H
Commercial Heat Pump (discontinued) 95202200D/H
Heat Pump 95202200D/H
Product Selector

Product Selector

Where to buy

Where to buy

Frequently Asked Questions

Frequently Asked Questions

close

Log in

To open and download technical documents you need to log in.

The provided details don't seem to be correct. Please try again.

Forgot password? Click here to reset.
Don't have an account? Register
close

Do you need support? Call free 0800 657 336

Rheem Logo
  • Rheem Products

  • All Products
  • For The Home
  • Commercial
  • Boiling Water
  • Solar Solutions
  • Tools & Resources

  • Brochure Library
  • Rheem Blog
  • FAQs
  • Product Selector
  • Video Guides
  • MyRheem Pro
  • Company Info

  • Contact Us
  • Find a Stockist
  • Fix My Rheem
  • Why Choose Rheem?
  • Careers
Rheem Logo
Call free 0800 657 336
NZ Made © Rheem® New Zealand Ltd.
All rights reserved. Privacy Policy.
NZ Made
We use cookies to improve user experience and analyse website traffic. By using Rheem NZ you accept our use of cookies.