Rheem Heat Exchanger
Heat Exchanger 0191751
Heat Exchanger 0191751
Product Specifications
Nominal Rating
100 kW
Inlet/Outlet Temp (Primary Side/Non-Potable)
80/60 °C
Pressure Drop (Secondary Side/Potable)
3.59 kPa
Pressure Drop (Primary Side/Non-Potable)
3.74 kPa
Connection
Male G1/14
Flow Rate (Primary Side/Non-Potable)
1.22 L/sec
Inlet/Outlet Temp (Secondary Side/Potable)
45/65 °C
Weight
9 kg
Flow Rate (Secondary Side/Potable)
1.21 L/sec
Warranty: Parts (Parts/Labour)
1 Year
Potable Side Pump and Pipe Sizing
Heat Exchanger Model |
Qty in Parallel | Output (kW) | Design Flow Rate | Minimum Potable Primary F & R Pipe Size (mm) | Pump Model / Speed Setting |
0191750 | 1 | 50 | 0.61 | 32 | UPS20-60N / 3 |
0191750 | 2 | 100 | 1.22 | 40 | UPS32-80N / 3 |
0191750 | 3 | 150 | 1.83 | 50 | UPS32-80N / 3 |
0191751 | 1 | 100 | 1.21 | 40 | UPS32-80N / 3 |
0191751 | 2 | 200 | 2.42 | 50 | UPS40-60/2FB / 2 |
0191751 | 3 | 300 | 3.63 | 65 | UPS40-60/2FB / 3 |
0191752 | 1 | 150 | 1.82 | 50 | UPS32-80N / 3 |
0191752 | 2 | 300 | 3.64 | 65 | UPS40-60/2FB / 3 |
0191752 | 3 | 450 | 5.46 | 80 | UPS50-120FB / 2 |
0191753 | 1 | 200 | 2.43 | 50 | UPS40-60/2FB / 3 |
0191753 | 2 | 400 | 4.86 | 80 | UPS50-120FB / 1 |
0191753 | 3 | 600 | 7.29 | 100 | UPS50-120FB / 3 |
0191754 | 1 | 250 | 3.03 | 65 | UPS40-60/2FB / 3 |
0191754 | 2 | 500 | 6.06 | 80 | UPS50-120FB / 3 |
0191754 | 3 | 750 | 9.09 | 100 | UPS80-120FB / 1 |
Note: Pipe sizing, pump selection and installation of the NON-POTABLE circuit is not covered by Rheem. Pipe and pump sizing is for portable water side only between the heat exchanger and storage tank/s and is based on 25m TOTAL pipe run and 20 x 90° bends. If the piping is beyond this scope, please contact Rheem for assistance.