Raypak Hot Water
Raypak 1292
Raypak 1292
Product Specifications
Max Storage Capacity
14500 Litres
Installation Location
Indoor
Weight Empty Approx
360 kg
Natural Gas Input
1289 MJ/hr
Natural Gas Output
285 kW
Inlet Connection
RC2½
ULPG Input
n/a MJ/hr
ULPG Output
n/a kW
Warranty: Parts (Parts/Labour)
1 Year
Warranty: Heat Exchanger (Parts/Labour)
5/1 Year
Dimensions H x W (includes high wind top)
1915 x 860 mm
Dimensions H x W (without high wind top)
1615 x 860 mm
Flue Connection
405 mm
Natural Gas Connection On/Off Models
R1½
Natural Gas Connection Modulating Models
R1½
Relief Valve Connection - On/Off Models
RC¾
Relief Valve Connections - Modulating Models
RC¾
Electrical Rating 240V 50Hz
100 Watts
Electrical Rating 240v 50Hz
100 Amps
Minimum Buffer Tank Capacity
650 Litres
Natural Gas Recovery per/hr @ 30°C rise
8170 Litres
Natural Gas Recovery per/hr @ 40°C rise
6128 Litres
Natural Gas Recovery per/hr @ 50°C rise
4902 Litres
Natural Gas Recovery per/hr @ 60°C rise
4085 Litres
Natural Gas Recovery per/hr @ 65°C rise
3771 Litres
Natural Gas Recovery per/hr @ 70°C rise
3501 Litres
Natural Gas Recovery per/hr @ 75°C rise
3268 Litres
Natural Gas Recovery per/hr @ 80°C rise
3064 Litres
Natural Gas Recovery per/hr @ 85C rise
2884 Litres
Maximum Flow Rate Modulating (10°C Rise)
6.31 Litres/sec
Maximum Flow Rate Modulating Pressure Drop
46 kPa
Maximum Flow Rate On/Off (15°C Rise)
4.54 Litres/sec
Maximum Flow Rate On/Off Pressure Drop
24 kPa
Minimum Flow Rate (20°C Rise)
3.4 Litres/sec
Minimum Flow Rate Pressure Drop
14 kPa
Back Clearance (Combustibles)
600 mm
Front Clearance (Combustibles)
750 mm
Left Clearance (Combustibles)
600 mm
Right Clearance (Combustibles)
600 mm
Ceiling Clearance (Combustibles)
1200 mm
Back Clearance (Non-Combustibles)
150 mm
Front Clearance (Non-Combustibles)
750 mm
Left Clearance (Non-Combustibles)
600 mm
Right Clearance (Non-Combustibles)
600 mm
Ceiling Clearance (Non-Combustibles)
1200 mm
Technical Documents

Raypak Operating & Fault Finding Manual for Type B Modulating Water Heaters
4.6 MB
4.6 MB
Raypak Operation & Fault Finding Manual for Type B On/Off Water Heaters
4.2 MB
4.2 MB